Metamaterial for Ultrasound Energy Transfer (2024/1 - 2025/12)
HS Kwon*, Z. Yu, X. Li, E. M. Dede, and T. Lee*, Advanced Materials, 2026 [Publication]
A flexible and lightweight acoustic metamaterial composed of air cavities encased in polydimethylsiloxane (PDMS) is introduced to enhance ultrasound power transfer. The metamaterial leverages the strong reflectivity of air cavity boundaries to concentrate incoming ultrasound, thereby improving the performance of piezoelectric energy harvesters. Experimental demonstration of a metamaterial enhanced ultrasound energy harvester (Meta-UEH) showed more than 100% increase in harvested power while maintaining robustness to deformation.
Figure 1
Design optimization and simulation of Meta-UEH. (a) A schematic illustration of UPT from a transducer to a Meta-UEH in water. The inset shows the metamaterial focusing the incoming acoustic energy onto the PZT. (b) Top: The cross-section of the proposed Meta-UEH showing its components. The outlines of the components on the cross-section are highlighted with red lines. Bottom: An engineering drawing of the Meta-UEH. The inner radius and width of the ring structure were optimized for maximum energy harvesting performance. (c) The impedance of baseline UEH. Solid lines represent the measured impedance of the fabricated baseline UEH shown in the inset. Dashed black and gray lines are the simulated impedance of a baseline UEH model, and the red line marks the resonance frequency. (d) The simulation model used to obtain the impedance presented as dashed lines in Figure 1c. (e) Top: Simulation model of the baseline UEH under a plane wave. Bottom: Simulation model of the Meta-UEH under a plane wave. Only one-third of the models are illustrated to show the cross-section. (f) Simulated performance of the baseline UEH with a 200 Ω load and the optimized Meta-UEH with a 2 kΩ load.
Figure 2
Fabrication and experimental demonstration of Meta-UEH. (a) An exploded-view drawing of the Meta-UEH showing assembled parts. The inset shows a magnified view of the cavities and the hole in the base. (b) Pictures of the fabricated Meta-UEH. (c) Measurement setup for characterizing the ultrasound transducer. The inset shows a magnified view of the transducer and hydrophone, along with a green dash-dotted line indicating the transducer axis along which sound pressure measurements were taken at 2 mm intervals. (d) Measured pressure amplitude along the ultrasound transducer axis. (e) Experimental setup for demonstrating the Meta-UEH. (f) Measured performance of the Meta-UEH with a 2 kΩ load and the baseline UEH with a 200 Ω load. Dotted lines are simulation results from Figure 1f.
Figure 3
Working principle and energy flow visualization of Meta-UEH. (a) The vertical and radial displacement of PZT in baseline UEH (top) and Meta-UEH (bottom). (b) Radial displacement of the PDMS of Meta-UEH at two different phases. The arrows indicate the displacement directions of the PDMS section between the backing and the ring structure. (c) Total acoustic pressure amplitude inside the PZT for baseline UEH and Meta-UEH. (d) A Sankey diagram showing the energy flow of the Meta-UEH. The links are not to scale for visual purposes. (e) Acoustic field measured at 1 cm from the ultrasound transducer. (f) Acoustic field measured at 10 cm from the ultrasound transducer. The red and black circles correspond to the areas covered by the 7 mm PZT disc diameter and the 9 mm ring structure inner diameter, respectively. (g) Reflected acoustic field measured 3.5 cm in front of the Meta-UEH. (h) Transmitted acoustic field measured 3.5 cm behind the Meta-UEH.
Figure 4
Demonstration of Meta-UEH under continuous wave in a reflective environment. (a,b) Simulated acoustic fields under continuous waves in a small water cylinder surrounded by reflective walls for (a) baseline UEH with 284 kHz ultrasound, and (b) Meta-UEH with 325 kHz ultrasound. (c) Simulation results for the UEHs in the 250 ~ 350 kHz frequency range. (d) Experimental setup for testing the UEHs in a small water container with continuous waves. (e) Top: Meta-UEH in natural configuration. Bottom: Meta-UEH in bent configuration. (f) Measured harvested power from the UEHs. (g) Experimental setup for evaluating the effect of air cavity deformation on Meta-UEH performance. (h) Left: Meta-UEH in bent configuration. Center: Side view of the bent Meta-UEH. Right: Meta-UEH in natural configuration shown for reference. (i) Meta-UEH performance in the bent configuration in a reflectionless setup. Performance of the baseline UEH and the Meta-UEH in the natural configuration from Figure 2f is also shown for comparison.